hohner

    Hohner Automation Ltd.


Home Email About Us Products Barriers Distributors Custom News

DHA-00X 'Angler' Downhole Absolute Pressure Transducer


 

Part Number: DHA - 00X

 

Inconel X-718 Wetted Parts

3x Burst Pressure Rating

 

Thread: 3/8" - 24 UNF - 2A

 

DHA-005 = 0...5,000 psi

DHA-010 = 0...10,000 psi

DHA-015 = 0...15,000 psi

DHA-020 = 0...20,000 psi

DHA-022 = 0...22,500 psi

DHA-025 = 0...25,000 psi

DHA-030 = 0...30,000 psi

 


Technical Data Connection Options
Operating temp: - 40...+   240 C J hook connection
- 40 ...+ 464 F Hook A +Excitation
Compensated Temp: +25...+175 C Hook B +Signal
+75...+347 F Hook C -Signal
Thermo Drift Zero: 0.01% FSO per C Hook D -Excitation
Thermo Drift Sense: 0.025% FSO per C Hook E RTD (Pt1000 or Pt100 optional)
Certification: Not for hazardous areas Hook F RTD (Pt1000 or Pt100 optional)
Weight: 0.1 lbs (30 g)
External Protection: 20k psi at 175C (347F) Install Torque 15-17 Nm
Material Housing: 17-4PH Stainless Steel Install Thread 3/8" - 24 UNF - 2A
Material Wetted Part: Inconel X-718 O-Ring 7.65Øx11.2x1.78
Vibration: 20g, from 10 to 100 Hz Backup O-Ring 7.9Øx10.5x0.8
Shock: 500g at 1ms
Pressure Range: 5k psi to 30k psi Precision and Scale
Over Pressure: 1.5x to 1.8x range Accuracy: 0.15% full scale
Burst Pressure: 3.0x range Non Linearity: 0.15% full scale
Non Repeatability: +/- 0.08% full scale
Electrical Data Hysteresis Error: 0.08% full scale
Excitation: 5 VDC Long Term Stability: +/- 0.1% full scale per year
Bridge Resistance: 1.5k ohm to 4.5k ohm Total Error Band: 0.15% full scale
Output Zero Pressure: +/- 2% full scale Error due Shock 0.01% of FSO per g
Full Scale Sense 4 +/-1 mV/V
Electrical Connection: Glass/Metal pins
Insulation Resistance: >= 500M ohm at 250V

Dimensions:


Hohner Corp. Tel:  1 905 563 4924 and 1 800 295 5693
5536 Regional Road 81 Fax: 1 905 563 7209
Beamsville, Ontario, L0R 1B3, Canada E-mail: hohner@hohner.com

Hohner Automation Ltd. Tel: +44 (0) 1978 363-888 and 0 845 658 2020
Units 14-16, Whitegate Industrial Estate Fax: +44 (0) 1978 364-586
Wrexham, North Wales, LL13 8UG, UK E-mail: uksales@hohner.com