Series M (INC-00X) Inclinometer (Ex d)


M   E K 0 - 3 6 X X - X X X X
 

|

 

Shaft

 

Output

  |  

|

    

Inclination Angle

| |

|

| 0060 = +/-60 degrees
| | 36 = Inclinometer | other inclination angles
  |   |   |  

available, please ask

| Shaft Size | Exit
| K0 = No Shaft | A = Axial
|   | R = Radial
Protection

|

E = IP66/67 Stainless Steel Connection
1 = 2m cable
3 = 10m cable
   5 = 20m cable

 

Zone 1, Class 2 Div 1


Technical Data Connection Options
Operating temp: - 20 ...+   60 degrees C Cable
-   4 ...+ 140 degrees F PS GND Black
Max frequency: 150 kHz PS 5 ... 24 V Red
Current consumption: 80 mA (max.) Output Axis X White
Power supply: 5...24V Output Axis Y Blue
Weight: 2.5Kg Zero Teach Yellow
Protection: IP 66/67
Housing: S. Steel Output
Humidity: Up to 98% permissible Axis X - 60o = 4mA and +60o = 20mA
Shock: 10g (6msec) Axis Y - 60o = 4mA and +60o = 20mA
Vibration: 5g (500 Hz)

Certifications
Does not require a barrier for use in hazardous areas, it is Flameproof, making the barrier redundant.
IP 66/X7
Ex d IIC (mining safety markings optional)
ATEX [Certificate]
IECEx [Certificate]
CSA [Certificate]
 

Mounting Instructions

Hook up the inclinometer with the connections as described.  Make sure power supply meets specifications.  Attach unit to machine or device and use the arrows indicating inclination as reference as to which axis the measurements take place.

 

Orientation of axis as standard is as follows:

X axis is 'AXIAL' and Y axis is 'RADIAL'

 

 

Dimensions


Hohner Corp. Tel:  1 905 563 4924 and 1 800 295 5693
5536 Regional Road 81 Fax: 1 905 563 7209
Beamsville, Ontario, L0R 1B3, Canada E-mail: hohner@hohner.com