hohner |
Hohner Automation Ltd. |
Home | About Us | Products | Barriers | Distributors | Custom | News |
RTC-001 'Cirneco' - Running Tension Line Sensor |
|
Part Number: RTC - 00X
4...20 mA 2 wire current loop output Both standard and Certified (Zone 0 Ex ia IIC optional)
Rated for 20,000kg 32mm diameter cable (Rated for 44,000lb 1.25" diameter cable)
MS6 Connector Standard
Can be made with optical encoders as an option to measure length of cable passing through, both certified and non-certified to hazardous areas.
Certified to ATEX, IECEx and CSA
Non certified version also available |
Technical Data | Connection Options | ||
Operating temp: | - 40 ...+ 60 degrees C | MS6, MS7, MS10 (available with junction box as well) | |
- 40 ...+ 140 degrees F | + Loop | Pin A | |
- Optional | -40....+ 85 degrees C | - Loop | Pin D |
-40... + 185 degrees F | |||
Load Cell Certification: | ATEX, CSA and IECEx | - Other connector types also available | |
Weight: | 24 lbs (11 kg) | ||
Protection: | IP 66 / X7 M | Capacities | |
Material Load Cell: | Stainless Steel | The load capacity can be adjusted by adding/removing | |
Material Chassis: | Aluminum | external spacers to raise/lower the central pulley. This | |
Material Wheels: | Aluminum | allows for various fixed positions to measure a combination | |
Power Supply: | 24 V | of forces and cable diameters from the same device. | |
Output Tolerance: | 0.25% of full scale | ||
Calibration Error: | Under 5% |
Certification |
|
Temp Effects: | Full shift 0.035%/10C | IP 66 and Ex ia IIC | |
From Load Cell | |||
Advantages | Best suited to work with the following MTL | ||
-Easy MS6, MS7 or MS10 connection | isolator: MTL5541 | ||
-One design allows for variable forces | |||
-Easy to switch between cable diameters |
Tension Spacers | ||
-Field replaceable load cell, in the event of a | The unit has 4x tension spacers at the top that can be | ||
failure, only the actual load cell is replaced | swung in and out to get the correct tension per cable | ||
diameter. This allows for many variations in min and max | |||
spans. On average the cable will bend about 10mm. |
Dimensions:
Hohner Corp. | Tel: 1 905 563 4924 and 1 800 295 5693 |
5536 Regional Road 81 | Fax: 1 905 563 7209 |
Beamsville, Ontario, L0R 1B3, Canada | E-mail: hohner@hohner.com |
Hohner Automation Ltd. | Tel: +44 (0) 1978 363-888 and 0 845 658 2020 |
Units 14-16, Whitegate Industrial Estate | Fax: +44 (0) 1978 364-586 |
Wrexham, North Wales, LL13 8UG, UK | E-mail: uksales@hohner.com |